Architecture

Edge-first, cloud-synced.

DYNVOLT runs on embedded Linux nodes deployed at every site. They poll Modbus TCP every 30 seconds, persist locally, and stream to the cloud when connectivity allows. When the internet connection drops, the plant keeps monitoring, alarming and enforcing its export limit.

At the plantedge nodelocal bufferkeeps polling every 30 sand controlling locallyClouddashboards · forecastsmarkets · reportslink downcatch-up
0
Inbound ports at the edge
30s
Modbus poll cadence
Months
Offline buffer
Signed
Config and secrets

Three planes. One platform.

Marketsyou or your BRP submitsCloudDYNVOLT platformEdge, on sitekeeps running offlinePlantyour equipmentnominationsMEMOHUPXSEEPEXOPCOMIBEXHEnExSDAC DEData storeevery string,every inverterForecastingper logger,P10 / P50 / P90Trader deskplans lockedbefore the gateAlerts & O&Mpeer-relative,auto-closingAI operatorproposes,you confirmReportsscheduled,PDF and CSVoutbound only · signed config · encrypted backupsDYNVOLT edge nodeembedded Linux at every plant30 spolling, every stringmonthsof data kept on siteset-pointsand export limit applied hereInvertersper stringData loggersSmartLoggerMetersModbus TCPWeatherirradiance, tempTransformerstemp, fansSensor nodesMQTTBatteryPCS, BMStelemetry ↑set-points ↓

What we built, and why.

Edge-resilient by default

A local buffer that holds months of data keeps every reading durable. When connectivity returns, the cloud catches up without gaps, so a WAN outage loses no data.

Control stays on site

Set-point write-back happens at the edge instead of through a cloud round-trip. With no WAN in the control path, curtailment and export limits keep working when the link drops.

Outbound only

The edge opens no inbound ports. It connects out to the control plane, receives configuration and secrets as signed envelopes, and every write lands in a hash-chained audit log. Role-based access on every API.

Open at the seams

Modbus TCP and MQTT in production, plus a public API with read and safe-write scopes for telemetry, alerts, work orders and reports. Plant control is not exposed. IEC 60870-5-104 is delivered as a project to your operator's specification.

Managed from the cloud

An edge agent on each node reports a heartbeat, applies the desired configuration from the control plane and ships encrypted backups off site.

FAQ

Architecture: frequently asked

Can't find what you're looking for? Talk to our team →

What happens if the edge node fails?
Control loops, alarms and the export limit run locally on the edge. A local buffer holding months of data, plus encrypted off-site backups mean history survives hardware failure. Recovery is a re-provision from signed configuration, not a rebuild.
What data leaves the plant?
Only the time-series payload your tenancy is configured for, over outbound-only encrypted connections. The edge accepts no inbound connections.
How is the platform updated?
Edge nodes pull GPG-signed update channels with signed configuration envelopes,.
What protocols are supported?
In production: Modbus TCP and MQTT. IEC 60870-5-104 is delivered as a project to your grid operator's specification. Other protocols are scoped per site. A public REST API is available for your own systems.
Is the platform multi-tenant or single-tenant?
Multi-tenant by default, with a central identity provider, per-tenant entitlements, and hash-chained audit logging. Single-tenant and on-prem arrangements are agreed case by case, so ask us.

Get a tailored architecture review.

A 30-minute call with an engineer covering the edge runtime, the security model and a deployment plan for your plants.

Request a demoSee the sensor nodes →